O B J E C T / O F F E R  No. 707099

 

 

ONE  CENTAUR  50  GAS  TURBINE  GENERATOR  PACKAGE

 

ORIGINAL DATE OF MANUFACTURER 1997.

21,867 FIRED HOURS FROM NEW

 

1.         GAS TURBINE

 

            -           Centaur 50 (T5701) Gas Turbine. Nominal 4.0 MW.

            -           Speed reducing gearbox.

            -           Flexible shear coupling.

            -           Vibration monitoring system (two channel - turbine and gearbox). 

 

GAS TURBINE AUXILIARY SYSTEMS

 

2.         GAS FUEL SYSTEM

 

            -           Pressure monitor.

            -           Primary and secondary shut off valves.

            -           Fuel control valve.

            -           Fuel control actuator.

            -           Polishing filter unit.

 

3.         LUBRICATION SYSTEM

 

            -           Main pump mechanically driven from gas turbine gearbox.

            -           AC motor driven pre/post pump.

            -           Duplex oil filter.

            -           Oil tank in skid base.

            -           Pressure and temperature controllers.

            -           Oil coalescer (supplied loose).

 

4.         ELECTRO-HYDRAULIC START SYSTEM

 

            -           Hydraulic start motor (gearbox mounted).

            -           Hydraulic pump (AC motor driven).

            -           Oil tank.

 

5.         COLD CRANK WATER WASH SYSTEM

 

            -           Cold crank water wash manifold

            -           Water wash trolley supplied loose incorporating:

                       

6.         AC GENERATOR (LEROY SOMER)

 

            -           Horizontal, 2 sleeve bearing, 4 pole.

            -           Salient pole brushless.

            -           Open air circuit.

            -           Enclosure IP21.

            -           Temperature rise F.

            -           Insulation Class F.

            -           Supply 3.3KV/3-phase/3 wire/50 Hz.

-           Continuous rating matched to gas turbine (total temperature basis) at 0.8pf across specified ambient range. 

-           Automatic voltage regulator including parallel operation CT's quad droop assembly, three phase sensing, power factor control and manual operation.  (AVR etc. mounted in control panel).

            -           CT's 3 off for protection.

            -           CT's 3 off for Dale instrumentation…

            -           VT between star point and earth for protection relays. 

            -           Stator winding temperature monitoring (2 RTD's per phase). 

            -           Drive end and non-drive end bearing temperature detection.

            -           Drive end and non-drive end bearing seismic vibration monitors.

            -           Anti condensation heaters.

 

OFF SKID CONTROL AND ELECTRICAL EQUIPMENT

 

7.         TURBINE CONTROL PANEL 

 

            -           Gas turbine/auxiliary systems/governor/load/T5 sequence controller

                        (Mitsubishi PLC).

            -           Visual display unit system interface.

            -           Turbine and alternator vibration monitoring equipment.

            -           T5 temperature indicator.

            -           Turbine speed indicator.

            -           Turbine hours run indicator.

            -           Turbine start counter.

            -           Hard wire PLC backup logic where required. 

-           Miscellaneous push buttons, switches and indicators as required by Dale Control System. 

            -           Miniature moulded case circuit breakers for circuit protection.

            -           Panel anti condensation heater and thermostat.

-           Additional panel mounted hardware including PLC computer serial interface module to enable remote monitoring and external systems interface.

            -           Panel ventilation fan.

            -           Panel interior light.

            -           PC power supply socket.

 

8.         ALTERNATOR CONTROL PANEL

 

-           Key pad operated electronic metering unit (V, Hz, A, kW, kWh, kVAR and PF).

            -           Bus/Mains and generator zero voltmeter. 

            -           Bus/Mains and generator dual scale frequency meter. 

            -           Synchroscope.

            -           Automatic synchronising equipment including check sync relay.

            -           Miscellaneous push buttons, switches and indicators. 

            -           Miniature moulded case circuit breakers for circuit protection.

            -           Panel anti-condensation heater and thermostat.

-           Loose items supplied with the alternator, for example the AVR, are also mounted in the control panel.

            -           Panel ventilation fan.

            -           Panel interior light.

 

9.         AUXILIARY SYSTEMS PANEL

 

            -           DC backup battery and charger.

            -           DC voltmeter and under voltage detection.

            -           Panel anti-condensation heater and thermostat.

            -           Panel ventilation fan.

            -           Panel interior light.

 

10.       DOCUMENTATION

           

            2 copies of the following supplied:

            -           Dale instruction manual.

            -           Full set of operation and maintenance manuals.

            -           Manufacturing programme.

            -           Drawings:

                        -           General arrangement.

                        -           Foundation loading.

                        -           Electrical schematics

                        -           Liquid schematics.

                        -           Fuel schematics.

 

11.       MISCELLANEOUS

 

            -           First fill of lubricating and hydraulic oil.

            -           Static test at Dale works.

            -           First years supply of consumables

            -           Outdoor Enclosure.

            -           GT combustion air intake filters, ductwork and attenuation.

            -           Enclosure ventilation fan.

            -           Fire and gas detection/fire fighting equipment.

            -           Enclosure ventilation inlet and outlet filters, ductwork and attenuation

            -           Power Transformer.

 

 

13.       SALES OPTIONS

 

            -           5 Year extended warranty and maintenance contract.

-                      Installation & Commissioning. - € Euros 50,000.00 except Iraq

Customer to provide engineer(s) with good quality single accommodation, food and transport upon arrival at works, at no cost to Contractor.

-                      Dual Fuel Conversion.

-                      60 Hz Conversion.

-                      Refurbished to Zero Hours. - € Euros 1,300,000.00 FOB European Port

Warranty will be 12 month from Installation or

5000 running hours, whichever is soonest.

-                      Upgraded Controls System.

-                      As is where is. – United Kingdom

-                      Delivered.

 

14.    SALES PRICE

 

-                     As is where is. – Europe  € 385,000,--

-                     All transport and shipping costs at buyers charge

 

Pictures:                                 attached, more pictures on request.

Viewing:                                to be agreed with us.

Remarks:                              1.) installation and putting into operation on request.

                                               2.) the plant is in excellent condition and finally inspected

by the AXA in April 2007.